"R-19 batts are extremely air permeable, and on long unobstructed rafter bays you've got rather a stack outcome. It won't have a massive number of air leakage to deliver some drying there. Also, Should the batts are unfaced or kraft-confronted, the drying towards the inside would be significant.

Hi Anyone. I see I am somewhat late to your social gathering on this thread but I hope someone can even now help me. From my issue line you are able to see I've rather your house. I am the home owner and disappointed with my leaky roof. I live in WI and my roof has asphalt shingles.

Builders resolve this issue by furring down or scabbing on extra framing under the rafters to deepen the rafter bays. A different approach is so as to add a layer of cross-hatched 2x4s, sixteen inches on Centre, mounted beneath the rafters."

Back again to the vent idea. I really Assume venting a roof which is airsealed in the inside effectively and built without the need of vent chutes is maybe The easiest way to Establish cathedral ceilings.

By Martin Holladay

The key reason why To place the additional insulation in contact with the underside on the roof is the fact that It is really tough to verify that you've effectively shut off all vents to your attic. However, if you truly do reach doing that, there ought to be no trouble. Having a blower door is possible, while difficult.

one. You need to get an engineer To judge the safety of your 2x4 rafters. "Furring down with 2x2s" isn't going to Enhance the means within your 2x4s to bear the snow load. It is really achievable that an engineer will recommend you to sister 2x8s or 2x10s on to your present 2x4 rafters.

Put in rigid foam insulation higher than the roof sheathing and air-permeable insulation amongst the rafters. This kind of assembly is designed to dry to the inside, Therefore the assembly ought to never include an interior polyethylene vapor barrier. If you decide on this process, it’s probable (even though not needed) to set up vent channels between the highest with the rigid foam and the highest layer of roof sheathing by setting up a number of parallel 2x4s — a person previously mentioned read the full info here Every single rafter — extending from soffit to ridge. (To learn more on this strategy, see How to put in Rigid Foam On Top of Roof Sheathing.)

Why not simply get it done appropriate furthermore Create with stress addressed roof sheathing. Even conventional plywood can manage wetting cycles persistently much more than our number 1 super low-cost OSB.

To stop moist inside air from calling chilly surfaces near the ridge, you need a real air barrier and an actual insulation layer. The right way to fix this issue is to reveal the rafter bays -- possibly from higher than or below, It is really your selection -- and pull out the fiberglass insulation. Put the fiberglass in a very dumpster. Then fill the rafter bays with spray polyurethane foam.

Have area about garage Centre with closets on both sides in between the closet kneewalls plus the eaves. Insulation above the room part is 6 inches of foam slabs sealed by "Good Things" spray-in foam. Earlier mentioned this ceiling foam and beneath the roof plywood, there are actually one inch x twenty. inch unobstructed foam encased ducts between the rafters for venting to the roof peak vent. The side sections outdoors the knee partitions are insulated with rolled fiberglass fiber with durovent ducts amongst the insulation and also the roof plywood. You will discover sizeable soffit vents at The bottom of your durovent ducts.

sips are great but within the coldest of climates they have got encountered issues. google dilemma programs in alaska - apparently a gaggle of residences there have been constructed although not plenty of awareness to depth for that plumbing and roof vents were being taken into consideration (Definitely air restricted foamed in penetrations), mated panel seams and fastener punctures triggered the top amount osb to rot. For sure the whole roofs wanted substitute.

2. Set up strong web-site-designed air flow baffles in Every rafter bay before you spray the foam. Like that you end up with a vented cathedral ceiling.

I've crafted log homes in the Yukon Territory in northern Canada for 30 a long time. Most log structures have cathedral ceilings. A lot of the roofs We've constructed are as follows (from the bottom up): log purloins, nominal 2" (2x6) t&g decking, 6mil poly, one 1/two" extruded polystyrene foam, 2x10 rafters on 24" centers, 7" fiberglass, 2x4 strapping, seven/sixteen OSB, underlayment (fifteen lb paper, 30lb felt, or now we would even use ice and h2o defend). There will be about an inch of air Room down below the strapping for both vertical and horizontal air circulation. All roofs are vented with strip vents on the eaves and vents during the soffit (2x6 t&g) at the height at both finishes. I might disagree that venting will not be needed in the event you stop the airflow on the warm facet, for two reasons. Very first it's very click for more difficult to stop all airflow, Specially with regular traditional techniques (ie chimney and plumbing vent penetrations through the roof) Now we have many tactics formulated over time to seal the vb in the eaves and gables, but there remain nail penetrations through the vb. Overall I believe we experienced quite limited seals but one particular could by no means say airtight.